Begin Infinifil™IV


 

 

 

 

 

The pool uses a normal pump, filter and plumbing. This allows standard circulation and filtering methods to be used for the normal circulation tasks.

A dedicated sump pump and filter are used for circulation between the catch basin and pool.

The correct water level in the sump is between the Fill and Pump sensors for operation of the infinite or negative edge feature.
If the water level goes below the fill level , the Infinifill™ automatically adds water until the proper level is reached, so the edge is maintained.

When someone enters the pool or wind blows water over the edge or a check valve bleeds back, the water level will rise in the catch basin. The Infinifill™ will automatically activate the pumps when the water rises to the Pump level. This will lower the water in the catch basin and return it to the pool and the edge will be established again.

When there is rainfall the overall system water level will rise and the edge is lost. When the water reaches the Dump level, water is removed from the catch basin and thus the pool.

 

Top of page.

 

Features

• Sensors are not metal probes or plates.

• No false water demands due to bathers or action of swimmers.

• Landscape damage is prevented from overfilling chlorine treated pools.

• Pool equipment damage is prevented due to improper water levels.

• The sensor is not affected by water chemistry or calcium and mineral residue left by evaporated water.

• Valves are irrigation quality and supplied with the system. Sprinkler or toilet valves are not used.

• If the fill or dump function operates longer than it normally should, the function will be ended. If normal conditions and operation occur again then the system will automatically operate normally.

 

 

Models

Infinifill™ IV Infinifill Water Level Control

• Includes 3 individual sensors with 24 foot cord

• Relays for circulation and edge pump included.

Option:
SC   Sensor cords in excess of 24 feet

Top of page.

 

Specifications:

Input Power

115 vac or 220 vac
Pumps Up to 2 1/2 H.P. pumps can be directly controlled.
Front Panel Indicators Wet or Dry Sensor Indicators, Power On, System Mode, Freeze Guard, Sensor Fault
Valves Two 3/4" Irrigation Diaphragm Valves
Valve Voltage 24 vac
Length of sensor cord Three individual sensors are provided with a 24 foot cord. Standard lengths up to 500 feet are available.
Controller Enclosure Metal outdoor enclosure. Powder Coated interior and exterior.
8" x 10" x 5"