Typical
Installation Examples For Existing Pools
There
are various ways that the Water Level Stabilizer can be installed on an
existing pool. There are almost as many different ways as there are pools.
Below are examples of a typical existing pool that has an existing manual
fill valve and line. Contact the factory to discuss the details of your
equipment and pool or pond.
 |
Typical
installation of a Fill System (Model 3005) for an existing pool
with a water fill line.
The
supplied 3/4" irrigation water valve is installed after the
water gate valve and the anti-siphon valve. The sensor cord is installed
in 3/4" PVC plumbing which enters the water flow via a "T".
The sensor cord is inserted in the fill line and exits the fill
line where the line terminates in the pool. The sensor is then attached
to the tile in the pool. The water from the filter exits a "T"
through a irrigation water valve to the drain. The WLS control box
mounts near a source of 115 vac or 220vac. 1/2" conduit is
installed from the power source to the WLS enclosure. The valve
control wires and the sensor cord exit the bottom of the enclosure.
|
| |
|
 |
Typical
installation of a Fill & Dump (Model 3105) for an existing pool
with a water fill line.
The
supplied 3/4" irrigation water valve is installed after the
water gate valve and the anti-siphon valve. The sensor cord is installed
in 3/4" PVC plumbing which enters the water flow via a "T".
The sensor cord is inserted in the fill line and exits the fill
line where the line terminates in the pool. The sensor is then attached
to the tile in the pool. The WLS control box mounts near a source
of 115 vac or 220vac. 1/2" conduit is installed from the power
source to the WLS enclosure. The valve control wires and the sensor
cord exit the bottom of the enclosure.
|
View
typical installations and information for new pools.
The
Water Level Stabilizer Systems Include:
Control unit.
One
irrigation quality water valve is provided for Model 3005systems. Two
water valves are provided for Model 3105 systems.
Sensor assembly with standard 24 foot cord.
The
Installer Should Provide:
Anti-Siphon valve or other devices required by national
and local plumbing codes.
Check valves if necessary.
Plumbing fittings.
Wire for power connections (18 gauge). System has 1/2" conduit fitting
holes.
Wire for valve connections (18 gauge).