Natural Purifier Field Test
[ ] Turn the output knob fully counterclockwise (off position). Place the power switch to the off position.
[ ] Disconnect the leads from the purifier chamber.
[ ] Turn on the circulation pump. (Note: The Purifier should not be on when the circulation pump is off.)
[ ] Turn the power switch on the Purifier to the "on" position. The "power indicator" will illuminate.
[ ] Advance the
output knob halfway and the "check electrodes" light will illuminate.
Rotate the output knob back to the off position.
[ ] Short the two electrode wires together. Rotate the output knob to an on position and some of the output lights will illuminate. Rotate the output knob back to the off position.
[ ] Turn off the pump and power the power light will turn off.
[ ] Turn the power switch on the purifier to the "off" position.
This completes a basic test of the Purifer System electronics.
[ ] Reconnect the leads to the purifier chamber.
[ ] Turn on the circulation pump.
[ ] Turn the power switch on the Purifier to the "on" position. The "power indicator" will illuminate.
[ ] Rotate the
output knob to an "on" position and some of the output lights will
illuminate.
The "check electrodes" light shall not be illuminated.
Rotate the
output knob back to the off position.
[ ] Turn off the pump and power the power light will turn off.
[ ] Turn the power switch on the purifier to the "off" position.
Results:
If the first test fails notify the factory (760) 878-2357.
If the first test passes and the second part fails the problem may be:
If all tests pass and a problem persists run the Purifier Output Test.